DataSheet.es    


PDF BTS611L1 Data sheet ( Hoja de datos )

Número de pieza BTS611L1
Descripción Smart Two Channel High-Side Power Switch
Fabricantes Infineon Technologies AG 
Logotipo Infineon Technologies AG Logotipo



Hay una vista previa y un enlace de descarga de BTS611L1 (archivo pdf) en la parte inferior de esta página.


Total 14 Páginas

No Preview Available ! BTS611L1 Hoja de datos, Descripción, Manual

PROFET® BTS611L1
Smart Two Channel High-Side Power Switch
Features
Overload protection
Current limitation
Short circuit protection
Thermal shutdown
Overvoltage protection (including load dump)
Fast demagnetization of inductive loads
Reverse battery protection1)
Undervoltage and overvoltage shutdown with
auto-restart and hysteresis
Open drain diagnostic output
Open load detection in ON-state
CMOS compatible input
Loss of ground and loss of Vbb protection
Electrostatic discharge (ESD) protection
Green Product (RoHS compliant)
AEC Qualified
Product Summary
Overvoltage protection Vbb(AZ)
43 V
Operating voltage
Vbb(on) 5.0 ... 34 V
channels:
each
both
parallel
On-state resistance RON
Load current (ISO) IL(ISO)
Current limitation IL(SCr)
200 100 m
2.3 4.4 A
4 4A
PG-TO263-7-2
Application
C compatible power switch with diagnostic feedback for 12 V and 24 V DC grounded loads
All types of resistive, inductive and capacitve loads
Replaces electromechanical relays, fuses and discrete circuits
General Description
N channel vertical power FET with charge pump, ground referenced CMOS compatible input and diagnostic
feedback, monolithically integrated in Smart SIPMOStechnology. Providing embedded protective functions.
3 IN1
6 IN2
ESD
5 ST
Voltage
source
V Logic
Voltage
sensor
Logic
Overvoltage
protection
Current
limit 1
Gate 1
protection
Level shifter
Rectifier 1
Charge
pump 1
Charge
pump 2
Limit for
unclam ped
ind. loads 1
Open load
Short to Vbb
detection 1
T em perature
sensor 1
Current
limit 2
Gate 2
protection
+ V bb
4
OUT1
1
PROFET
Level shifter
Rectifier 2
Limit for
unclam ped
ind. loads 2
Open load
Short to Vbb
GND detection 2
2 Signal GND
T em perature
sensor 2
OUT2
7
R O1
R O2
GND
Load
Load GND
1) With external current limit (e.g. resistor RGND=150 ) in GND connection, resistor in series with ST
connection, reverse load current limited by connected load.
Data Sheet
1
2013-10-11

1 page




BTS611L1 pdf
BTS611L1
Parameter and Conditions, each channel
at Tj = 25 °C, Vbb = 12 V unless otherwise specified
Symbol
Protection Functions9)
Initial peak short circuit current limit (pin 4 to 1
or 7)
Tj =-40°C:
Tj =25°C:
Tj =+150°C:
Repetitive short circuit shutdown current limit
Tj = Tjt (see timing diagrams, page 11)
Output clamp (inductive load switch off)
at VOUT = Vbb - VON(CL)
IL= 40 mA:
Thermal overload trip temperature
Thermal hysteresis
Reverse battery (pin 4 to 2) 10)
Reverse battery voltage drop (Vout > Vbb)
IL = -1.8 A, each channel
Tj=150 °C:
IL(SCp)
IL(SCr)
VON(CL)
Tjt
Tjt
-Vbb
-VON(rev)
Values
Unit
min typ max
5.5 9.5
4.5 7.5
2.5 4.5
-- 4
41 47
150 --
-- 10
-- --
-- 610
13 A
11
7
-- A
53 V
-- °C
-- K
32 V
-- mV
Diagnostic Characteristics
Open load detection current
(on-condition)
Open load detection voltage11)
Tj=-40 °C:
Tj=25 ..150°C:
(off-condition)
Tj=-40..150°C:
Internal output pull down
(pin 1 or 7 to 2), VOUT=5 V, Tj=-40..150°C
IL (OL)
VOUT(OL)
RO
10 -- 200 mA
10 -- 150
2 3 4V
4 10 30 k
9) Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
10) Requires 150 resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 8).
11) External pull up resistor required for open load detection in off state.
Data Sheet
5
2013-10-11

5 Page





BTS611L1 arduino
Timing diagrams
Figure 1a: Vbb turn on:
IN1
IN2
V bb
V
OUT1
V
OUT2
ST open drain
Figure 2a: Switching a lamp:
IN
ST
BTS611L1
Both channels are symmetric and consequently the diagrams
are valid for each channel as well as for permuted channels
Figure 2b: Switching an inductive load
IN
t
ST d(ST)
*)
V
OUT
IL
t I L(OL)
t
*) if the time constant of load is too large, open-load-status may
occur
Figure 3a: Short circuit
shut down by overtempertature, reset by cooling
IN other channel: normal operation
V
OUT
I
L
Data Sheet
IL
IL(SCp) IL(SCr)
t
ST
t
Heating up may require several milliseconds, depending on
external conditions
11 2013-10-11

11 Page







PáginasTotal 14 Páginas
PDF Descargar[ Datasheet BTS611L1.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
BTS611L1Smart Two Channel Highside Power SwitchSiemens Semiconductor Group
Siemens Semiconductor Group
BTS611L1Smart Two Channel High-Side Power SwitchInfineon Technologies AG
Infineon Technologies AG
BTS611L1E3128ASmart Two Channel Highside Power SwitchSiemens Semiconductor Group
Siemens Semiconductor Group
BTS611L1E3128ASmart Two Channel Highside Power SwitchInfineon Technologies AG
Infineon Technologies AG

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar