FEATURES
High accuracy, less than 0.1% error over a
dynamic range of 500:1
High stability during calibration, the fluctuation
of output CF is less than 0.1%.
Low drift, the gain variety is less than 0.1%
when input frequency changes from 45Hz to 65Hz
Single 5V Supply, Static Power 25mW(typical),
Power solution only with Resistor & Capacitor can be
adopted.
The Low Frequency Output (F1, F2) can drive
motor directly;
The High Frequency Output (CF) can be used in
calibration and data processing.
Selectable between the arithmetic sum of the
three-phase active energies and the absolute value
sum of these energies.
Measure positive active power and negative
active power.
Anti-Fault, the Logic Output REVP indicates a
Potential Miswiring or Negative Power for each
phase.
On-chip Creep Protection.
On-chip Power Supply Monitoring.
On-chip Reference 2.42V ± 8%,with External
Overdrive Capability.
SOP24 package.
Interrelated patents are pending
GENERAL DESCRIPTION
The BL0952A/BL6513/BL6511 is the chief IC of
the three-phase electrical meter and a high accuracy
energy measurement IC. With low power design,
static power is only 25mW. Based on the features such
as superior accuracy, high stability and simple
peripheral circuit, the BL0952A/BL6513/BL6511 is
compatible with 3-phase 3-wire and 3-phase 4-wire
configurations.
BL0952A/BL6513/BL6511 is based on digital
signal processing. BL0952A/BL6513/BL6511 can
measure positive active power and negative active
power; can select the way to calculate the sum of the
three-phase active powers, between the arithmetic
sum and the absolute value sum.
The high frequency output CF can be used in
calibration and data processing. The low frequency
outputs F1 and F2 can be used to drive a pulse-motor
or an electromechanical counter. In this way, the
power can be measured and the energy can be
recorded.
The internal phase matching circuitry ensures
that the current and voltage channels are phase
matched.An internal no-load threshold ensures that
the BL0952A/BL6513/BL6511 does not exhibit any
creep when there is no load.
The BL0952A/BL6513/BL6511 consider
emphatically the need of stability during calibration,
the measure data of mass products show that the
output pulse ripple of CF is less than 0.1%.
System Diagram Block
http://www.belling.com.cn
Fig.1 Functional block diagram
-1-
Total 1 Pages
4/21/2009

PagesPages 13
Télécharger [ BL6513 ]


Fiche technique recommandé

No Description détaillée Fabricant
BL6511 Three-phase Active Energy Meter SHANGHAI BELLING
SHANGHAI BELLING
BL6512 With phase-phase metering chip output SHANGHAI BELLING
SHANGHAI BELLING
BL6513 Three-phase Active Energy Meter SHANGHAI BELLING
SHANGHAI BELLING
BL6514 Phase active power metering chip SHANGHAI BELLING
SHANGHAI BELLING

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche