Número de pieza | NC12S0A0V40 | |
Descripción | DC/DC Power Modul | |
Fabricantes | Delta Electronics | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de NC12S0A0V40 (archivo pdf) en la parte inferior de esta página. Total 14 Páginas | ||
No Preview Available ! Delphi NC40 Series Non-Isolated Point of Loadwww.DataSheet4U.com
DC/DC Power Modules: 12Vin, 0.9V-5Vout, 40A
The Delphi NC40 Series, 12V input, single output, non-isolated point of
load DC/DC converters are the latest offering from a world leader in
power systems technology and manufacturing ― Delta Electronics,
Inc. The NC40 series operates from a 12V nominal input, provides up
to 40A of power in a vertical or horizontal mounted through-hole
package and the output can be resistor- or voltage-trimmed from
0.9Vdc to 5.0Vdc. NC40 series has built-in current sharing control and
multiple NC30/NC40 series modules could be paralleled together to
provide even higher output currents. NC40 series provides a very cost
effective point of load solution. With creative design technology and
optimization of component placement, these converters possess
outstanding electrical and thermal performance, as well as extremely
high reliability under highly stressful operating conditions.
DATASHEET
DS_NC12S40A_02072007
FEATURES
High Efficiency:
92% @ 12Vin, 5V/40A out
Voltage and resistor-based trim
No minimum load required
Output voltage programmable from
0.9Vdc to 5.0Vdc via external resistors
Fixed frequency operation
Input UVLO, output OVP, OTP, OCP, SCP
Remote ON/OFF (default: positive)
Power good output signal
Output voltage sense
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS 18001 certified manufacturing
facility
UL/cUL 60950 (US & Canada) Recognized,
and TUV (EN60950) Certified
CE mark meets 73/23/EEC and 93/68/EEC
directives
OPTIONS
Vertical or horizontal versions
Negative On/Off logic
APPLICATIONS
DataCom
Distributed power architectures
Servers and workstations
LAN/WAN applications
Data processing applications
1 page ELECTRICAL CHARACTERISTICS CURVES (CON.)
Figure 13: Output ripple & noise at 12Vin, 3.3V/40A out
Figure 14: Output ripple & noise at 12Vin, 5V/40A out
Figure 15: Turn on delay time at 12Vin, 0.9V/40A out
Ch2:Vin Ch3:Vout Ch4:PWRGD
Figure 16: Turn on delay time Remote On/Off, 0.9V/40A out
Ch2:ENABLE Ch3:Vout Ch4:PWRGD
Figure 17: Turn on delay time at 12Vin, 5V/40A out
Ch2:Vin Ch3:Vout Ch4:PWRGD
DS_NC12S40A_02072007
Figure 18: Turn on delay time Remote On/Off, 5V/40A out
Ch2: ENABLE Ch3:Vout Ch4:PWRGD
5
5 Page THERMAL CURVES (NC12S0A0V40)
Test Section for NC12S0A0V40
FACING PWB
PWB
MODULE
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
AIR FLOW
50.8 (2.0”)
19 (0.75”)
38 (1.5”)
Note: Wind Tunnel Test Setup Figure Dimensions are in
millimeters and (Inches)
Figure 36: Temperature measurement location
* The allowed maximum hot spot temperature is defined at 125℃
NC12S0A0V40(Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A)
@ Vout = 5V(Either Orientation)
45
40
35
30
25
Natural
Convection
20
100LFM
200LFM
15
300LFM
400LFM
10
500LFM
600LFM
5
0
25 35 45 55 65 75 85
Ambient Temperature (℃)
Figure 37: Output current vs. ambient temperature and air
velocity@ Vout=5V(Either Orientation)
NC12S0A0V40(Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A)
@ Vout = 3.3V(Either Orientation)
45
40
35
30
25
Natural
Convection
20
100LFM
200LFM
15 300LFM
400LFM
10 500LFM
600LFM
5
0
25 35 45 55 65 75 85
Ambient Temperature (℃)
Figure 38: Output current vs. ambient temperature and air
velocity@ Vout=3.3V(Either Orientation)
NC12S0A0V40(Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A)
45
@ Vout = 1.5V(Either Orientation)
40
35
30
25
Natural
Convection
20
100LFM
200LFM
15 300LFM
400LFM
10
500LFM
600LFM
5
0
25 35 45 55 65 75 85
Ambient Temperature (℃)
Figure 39: Output current vs. ambient temperature and air
velocity@ Vout=1.5V(Either Orientation)
NC12S0A0V40(Standard) Output Current vs. Ambient Temperature and Air Velocity
Output Current(A)
@ Vout = 0.9V(Either Orientation)
45
40
35
30
25
Natural
Convection
20
100LFM
200LFM
15
300LFM
400LFM
10
500LFM
600LFM
5
0
25 35 45 55 65 75 85
Ambient Temperature (℃)
Figure 40: Output current vs. ambient temperature and air
velocity@ Vout=0.9V(Either Orientation)
DS_NC12S40A_02072007
11
11 Page |
Páginas | Total 14 Páginas | |
PDF Descargar | [ Datasheet NC12S0A0V40.PDF ] |
Número de pieza | Descripción | Fabricantes |
NC12S0A0V40 | DC/DC Power Modul | Delta Electronics |
Número de pieza | Descripción | Fabricantes |