DataSheetWiki


6EP13363BA00 fiches techniques PDF

Siemens - SITOP Power Supplies

Numéro de référence 6EP13363BA00
Description SITOP Power Supplies
Fabricant Siemens 
Logo Siemens 





1 Page

No Preview Available !





6EP13363BA00 fiche technique
www.DataSheet4U.com
SITOP Power Supplies
Switched Mode Regulated Technology
Power supplies, single-phase
Description
SITOP switched mode power
supplies offer high efficiency,
safe electrical isolation (SELV)
and low weight.
Different versions are available
depending on the output cur-
rent and application required.
The 2.5 A, 5 A and 10 A power
supplies are the first members
of a generation of 24 VDC
power supplies, called SITOP
smart.
They come with a 1/3 smaller
width compared to the former
generation, ATEX and UL class
1, div 2 agency approvals for
use in hazardous locations and
a power boost function to serve
high inrush loads.
Power supplies are suitable for
worldwide single-phase net-
works. Every power supply pro-
vides LED status display,
adjustable output voltage and
can be snapped on DIN rail.
Power supplies meet
• radio interference suppres-
sion class B,
• ambient temperature range
from 0 °C to +60 °C.
Selection and ordering data
Design
Input
voltage,
rated value
Ue Rated
24 VDC power supplies
* 0.375 A
48 – 220 VDC
(30 – 264 VDC/
30 – 187 VAC)
* 0.5 A
120 – 230 VAC
(93 – 264 VAC)
Output
voltage,
rated value
Ua Rated
Current,
rated
value
Ia Rated
Dimensions
(W x H x D)
mm
24 VDC ±2% 0.375 A 22.5 x 80 x 91
24 VDC ±2% 0.5 A 22.5 x 80 x 91
N
Limitation of input current harmonics according to EN 61 000-3-2.
2.5 A
120 – 230 VAC
(85 – 132 VAC/
170 – 264 VAC)
24 VDC ±3% 2.5 A 33 x 125 x 125
N
N
Limitation of input current harmonics according to EN 61 000-3-2
5A
120 – 230 VAC
24 VDC ±3% 5 A
50 x 125 x 125
(85 – 132 VAC/
170 – 264 VAC)
5A
120 – 230 VAC
24 VDC ±3% 5 A
50 x 125 x 125
(85 – 132 VAC/
170 – 264 VAC)
Limitation of input current harmonics according to EN 61 000-3-2
10 A
120 – 230 VAC
(85 – 132 VAC/
170 – 264 VAC)
24 VDC ±3% 10 A
70 x 125 x 135
10 A
120 – 230 VAC
(85 – 132 VAC/
170 – 264 VAC)
24 VDC ±3% 10 A
70 x 125 x 135
Deg. of protection IP 65, adapted to ET 200X; Wall mounting radio interference
suppression class A, ambient temperature -20°C to 55°C
10 A
120 – 230 VAC
(93 – 132 VAC/
187 – 264 VAC)
24 VDC ±3% 10 A
140 x 270 x 126
Order No.
6EP17312BA00
6EP13312BA10
6EP13322BA10
6EP13332BA01
6EP13332AA01
6EP13342BA01
6EP13342AA01
6EP13342CA00
Weight
approx.
kg
0.2
0.2
0.4
0.5
0.5
0.8
0.8
1.7
Limitation of input current harmonics according to EN 61 000-3-2
20 A
120 – 230 VAC
(90 – 132 VAC/
187 – 264 VAC)
24 VDC ±3% 20 A
280 x 125 x 92
3 VDC to 52 VDC power supply
Limitation of input current harmonics to according EN 61 000-3-2,
adjustable output voltage 3 V – 52 V, output max. 10 A or 120 W
max.
10 A
or
120 W
120 – 230 VAC
(85 – 132 VAC/
170 – 264 VAC)
3 – 52 VDC
± 1%
10 A
75 x 125 x 125
6EP13362BA00
6EP13532BA00
2.0
0.9
* without adjustable output voltage.
Further information is provided in catalog KT 10.1 or: www.siemens.com/sitop
Siemens Energy & Automation, Inc.
Industrial Controls Catalog
15/21

PagesPages 2
Télécharger [ 6EP13363BA00 ]


Fiche technique recommandé

No Description détaillée Fabricant
6EP13363BA00 SITOP Power Supplies Siemens
Siemens

US18650VTC5A

Lithium-Ion Battery

Sony
Sony
TSPC106

PCI Bus Bridge Memory Controller

ATMEL
ATMEL
TP9380

NPN SILICON RF POWER TRANSISTOR

Advanced Semiconductor
Advanced Semiconductor


www.DataSheetWiki.com    |   2020   |   Contactez-nous  |   Recherche