DataSheetWiki


AD5012N2LM fiches techniques PDF

Emerson - AC-DC / External Freestanding Medical Adapter

Numéro de référence AD5012N2LM
Description AC-DC / External Freestanding Medical Adapter
Fabricant Emerson 
Logo Emerson 





1 Page

No Preview Available !





AD5012N2LM fiche technique
Embedded Power for
Business-Critical Continuity
AD50 Medical Series
50 Watts
Total Power:
Input Voltage:
# of Outputs:
50 Watts
90 - 264 VAC
Single
Rev. 09.19.08_108
AD50 Medical Series
 of 2
RoHS
Special Features
• Universal AC input
• Fully regulated output
• EN61000-3-2 compliant
• Input power <74 watts
• Overcurrent and overvoltage
protection
• High efficiency
• High MTBF
• IEC320 AC input receptacle
3 pin (type C6) - AD5012N3LM
ww w2.pDianta(tSyhpeeeCt48U).c-oAmD5012N2LM
• Built in EMI filter
• (CISPR 22 Class B)
• AC input fuse
• Complies with One Watt
Input Energy Star / Blue Angel
Requirement
• CE Mark EMC & LVD
Safety
CSAUL UL 60601-1
CSA 60601-1
VDE 60601-1
CE Mark LVD and EMC
Electrical Specifications
Input
Input ra­nge:
90-264 Vac (wide range)
Frequency:
47-63 Hz
Inrush current:
60A maximum @ 230VAC, cold start 25C°
Input current:
2 A maximum
Efficiency:
80% typical
EMI/RFI:
FCC Part 15, Class B & EN55022 (CISPR 22) Class B
Safety ground
leakage current:
300µA maximum@ 50/60 Hz, 264 VAC input - AD5012N3L
100µA maximum@ 50/60 Hz, 264 VAC input - AD5012N2L
Output
Maximum Power (Po):
Hold-up time:
50 W
17 ms. minimum at full load @ 100 Vac, 47 Hz
Overvoltage protection:
Overcurrent protection:
Cable/connector :
16 - 20 V
Latching type, recycle AC to reset.
Output short circuit protection auto recover
Overload protection @ 110 - 120% above maximum rating
DC cable with 2.5 mm x 5.5 mm barrel plug
DC plug center +v
DC plug outer -v
Environmental Specifications
Operating temperature: 5° to +40°C ambient
Storage temperature:
Electromagnetic
susceptibility:
-40°C to +70°C
Designed to meet EN61000-4-2, -4, -5, level 4;
EN61000-4-3, -6, 10v/m; EN61000-4-8, -11; EN61000-3-3
and EN61000-3-2 Class A
Humidity:
MTBF demonstrated:
Operating; non-condensing 10% to 90% RH
>300,000 hours at full load and 25°C ambient conditions

PagesPages 2
Télécharger [ AD5012N2LM ]


Fiche technique recommandé

No Description détaillée Fabricant
AD5012N2L AC-DC / External Freestanding Adapter Emerson
Emerson
AD5012N2LM AC-DC / External Freestanding Medical Adapter Emerson