DataSheet.es    


PDF ZX1 Data sheet ( Hoja de datos )

Número de pieza ZX1
Descripción Compact displacement sensing
Fabricantes Omron 
Logotipo Omron Logotipo



Hay una vista previa y un enlace de descarga de ZX1 (archivo pdf) en la parte inferior de esta página.


Total 16 Páginas

No Preview Available ! ZX1 Hoja de datos, Descripción, Manual

­ZX1 & ZX2 SERIES
­C o m p a c t d i s p l a c e m e n t s e n s i n g
» » ­A l l - i n - o n e h o u s i n g
» »­H i g h l y s t a b l e – a ny s u r fa c e
» »­P l u g & p l a y – s i m p l e o p e r a t i o n
Free Datasheet http://www.Datasheet4U.com

1 page




ZX1 pdf
5
­Measuring ‘run-out’
­Measuring the remaining
amount of a coil
­Confirming the number of washers
NG
­Measuring the depth of tread
Free Datasheet http://www.Datasheet4U.com

5 Page





ZX1 arduino
Ratings and Specifications
Model
NPN output
Item
Measurement range
Light source (wave length)
PNP output
Spot diameter (typical)
(Defined at the measurement center distance) *2
Power supply voltage
Current consumption
Control output
Analog output
Indicators
Response time
Judgment output
Laser OFF input
Zero reset input
Temperature characteristic *3
Linearity *4
Resolution *5
Ambient illumination
Ambient temperature
Ambient humidity
Dielectric strength
Vibration resistance (destruction)
Shock resistance (destruction)
Degree of protection *6
Connection method
Weight
(packed state/
sensor only)
Materials
Accessories
Pre-wired models (2 m)
Pre-wired models (5 m)
Pre-wired connector models
(0.5 m)
ZX1-LD50A61
ZX1-LD50A66
ZX1-LD100A61
ZX1-LD100A66
ZX1-LD300A61
ZX1-LD300A66
ZX1-LD50A81
ZX1-LD50A86
ZX1-LD100A81
ZX1-LD100A86
ZX1-LD300A81
ZX1-LD300A86
50 ± 10 mm
100 ± 35 mm
300 ± 150 mm
Visible-light semiconductor laser
(wavelength: 660 nm, 1 mW max., IEC/EN Class 2, FDA Class II *1)
0.17 mm dia.
0.33 mm dia.
0.52 mm dia.
ZX1-LD600A61
ZX1-LD600A66
ZX1-LD600A81
ZX1-LD600A86
600 ± 400 mm
0.56 mm dia.
10 to 30 VDC, including 10% ripple (p-p)
250 mA max. (at power supply voltage 10 VDC)
Load power supply voltage: 30 VDC max., Load current: 100 mA max.
(Residual voltage: 1 V max. (load current 10 mA or less), 2 V max. (load current of 10 to 100 mA))
Current output: 4 to 20 mA, maximum load resistance: 300 Ω
Digital display (red), output indicator (OUT1, OUT2) (orange), zero reset indicator (orange), menu indicator (orange), laser ON indicator
(green), and smart tuning indicator (blue)
Super-high-speed (SHS) Mode: 1 ms
High-speed (HS) Mode: 10 ms
Standard (Stnd) Mode : 100 ms
200 ms max.
200 ms max.
0.03% F.S./°C
0.04% F.S./°C
±0.15% F.S.
±0.25% F.S.
±0.25% F.S.
(200 to 600 mm)
±0.5% F.S.
(entire range)
2 μm
7 μm
30 μm
80 μm
Illumination on received light surface:
7,500 lx or less (incandescent light)
Illumination on received light surface:
5,000 lx or less (incandescent light)
Operating: -10 to +55°C, Storage: -15 to +70°C (with no icing or condensation)
Operating and storage: 35% to 85% (with no condensation)
1,000 VAC, 50/60 Hz, 1 minute3
10 to 55 Hz, 1.5-mm double amplitude, 2 hours each in X, Y, and Z directions
500 m/s2 3 times each in X, Y, and Z directions
IEC 60529, IP67
Pre-wired model (Standard cable length: 2 m, 5 m)
Pre-wired connector model (Standard cable length: 0.5 m)
Approx. 240 g / Approx. 180 g
Approx. 270 g / Approx. 210 g
Approx. 450 g / Approx. 330 g
Approx. 480 g / Approx. 360 g
Approx. 170 g / Approx. 110 g
Approx. 200 g / Approx. 140 g
Case and cover: PBT (polybutylene terephthalate), Optical window: Glass, Cable: PVC, Mounting hole part: SUS303
Instruction sheet and Laser warning label (English)
Note: False detection outside the measurement range can occur in the case of an object with high reflectance.
*1. Classified as Class 2 by EN60825-1 criteria in accordance with the FDA standard previsions of Laser Notice No. 50. Notification to CDRH planned. (Center for Devices and Radiological Health)
*2. Spot diameter: Defined as 1/e2 (13.5%) of the central intensity at the measurement center distance.
False detections can occur in the case there is light leakage outside the defined region and the surroundings of the target object have a high reflectance in comparison to the target object.
Accurate measurements may not be possible for workpieces that are smaller than the spot diameter.
*3. Temperature characteristic: Value for the case the space between the sensor and Omron’s standard target object is secured by an aluminum jig. (Measured at the measurement center distance)
*4. Linearity: Indicates the error with respect to the ideal straight line of the displacement output in the case of measuring Omron’s standard target object (white ceramic) at a temperature of 25°C.
Linearity and measured value may vary depending on target object.
*5. Resolution: Defined in Standard Mode for Omron’s standard target object (white ceramic) after executing Smart Tuning.
The resolution indicates the repetition accuracy for a still workpiece. Not an indication of the distance accuracy.
Resolution performance may not be satisfied in a strong electromagnetic field.
*6. IP67 protection applies to the connector on pre-wired connector models if an extension cable is connected.
Free Datasheet http://www.Datasheet4U.com

11 Page







PáginasTotal 16 Páginas
PDF Descargar[ Datasheet ZX1.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
ZX-LD100ZX Series Smart SensorsOmron
Omron
ZX-LD100LZX Series Smart SensorsOmron
Omron
ZX-LD300ZX Series Smart SensorsOmron
Omron
ZX-LD300LZX Series Smart SensorsOmron
Omron

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar