UEP 6000 Service Manual
VME 602X – Series
Service Manual
1
10/16/06
Free Datasheet http://www.Datasheet4U.com

1 page




VME602X pdf
2) Power supply operation and configuration file
Please save the present configuration of the connected power supply as a file to hard or floppy disk before
changing any item. It is recommended to keep all configuration files to allow an easy restore of the configuration
data at a later time.
3) Power supply set-up and calibration
To access any (available) parameter point the cursor on it and click with the left mouse button.
If you do not see the parameters mentioned below, click on the “Configuration” menu. This will bring up a
window that allows you to choose which parameters are shown.
WIENER Plein & Baus Corp. / GmbH is not responsible for any damage of the power supply, VME crate or of
any module inside the crate caused by changing the factory prepared configuration and calibration of the power
supply. To protect the UEP 602X power supply for unauthorized access there is software write protection. All
parameters that are gray are write protected.
UEP 6000 Service Manual
5
10/16/06
Free Datasheet http://www.Datasheet4U.com

5 Page





VME602X arduino
Monitoring:Imin Software minimum current limit
Standard settings: No minimum (0)
The minimum current limit is the minimum allowed current for a given channel. If
the current for that channel ever reaches or drop below the minimum value, the
power supply will turn off with an “Undercurrent “ error.
Value is the minimum allowed current for the channel.
Minimum Value is the minimum allowed value.
Maximum Value is the maximum allowed value.
Exponent gives the number of digits after the decimal.
Monitoring:Umax Software maximum cuurent limit
Standard settings: 100% of Hardware Limits
The maximum cuurent limit is the maximum allowed current for a given channel. If
the cuurent of that channel ever reaches or exceeds the maximum value, the power
supply will turn off with an “Overcurrent “ error.
UEP 6000 Service Manual
11
10/16/06
Free Datasheet http://www.Datasheet4U.com

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet VME602X.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
VME602XService ManualETC
ETC

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar