DataSheet39.com

What is L10-NA300P3?

This electronic component, produced by the manufacturer "Sprecher Schuh", performs the same function as "UL/CSA Fused Disconnect Switches".


L10-NA300P3 Datasheet PDF - Sprecher Schuh

Part Number L10-NA300P3
Description UL/CSA Fused Disconnect Switches
Manufacturers Sprecher Schuh 
Logo Sprecher Schuh Logo 


There is a preview and L10-NA300P3 download ( pdf file ) link at the bottom of this page.





Total 14 Pages



Preview 1 page

No Preview Available ! L10-NA300P3 datasheet, circuit

Disconnect Switches
Series L10
UL/CSA Fused Disconnect Switches
Switch (typical)
Amp
Rating
(A)
30
60
Maximum Horsepower
1 Ø (60Hz)
Three Phase (60Hz)
DC
120V 240V 200V 240V 460V 600V 125V 250V Catalog Number
UL Class J and CSA HRCI-J Fuses
o b s o l e t e2 3 7.5 7.5 15 20 3 5 L10-NJ030P3
3 10 15 15 30 50 5 10 L10-NJ060P3
100 ~ 7.5 ~ 30 60 75 ~ 20 L10-NJ100P3
200 ~ 10 ~ 60 125 150 ~ 40 L10-NJ200P3
400 ~
30 2
~ 100 125 250 300 ~
CSA HRCII-C Fuses
3 7.5 7.5 15 20 ~
50 L10-NJ400P3
~ L10-NA200P3
60 3 10 15 15 30 50 ~ ~ L10-NA300P3
100 ~ 15 25 30 60 75 ~ ~ L10-NH100P3
200 ~ 30 50 60 125 150 ~ ~ L10-NH200P3
400 ~ 50 100 125 250 300 ~ ~ L10-NH400P3
UL/CSA Non-Fused Disconnect Switches
Switch (typical)
Amp
Rating
(A)
1 Ø (60Hz)
120V 240V
Maximum Horsepower
Three Phase (60Hz)
200V 240V 460V 600V
DC
125V 250V
Catalog Number
30 2 3 7.5 7.5 15 20 3 5 L10-NN030P3
60 3 10 15 15 30 50 5 10 L10-NN060P3
L 100 ~ 7.5 ~ 30 60 75 ~ 20 L10-NN100P3
200 ~ 10 ~ 60 125 150 ~ 40 L10-NN200P3
400 ~ ~ 100 125 250 300 ~ 50 L10-NN400P3
Note: L10 Fusible and Non-fusible Disconnect Switches with
dimension codes D, E & F require lugs. Sprecher + Schuh lugs
available on page L49.
Price
362 A1
471 B1
744 C1
1641 D1
3136 F1
362 A1
471 B1
744 D1
1641 E1
3136 F1
Price
305 A2
414 B2
744 C1
1641 D1
3136 F1
Ordering Instructions
• Specify Disconnect Switch catalog number (page L46)
• Specify desired switch handle catalog number (page L47)
• Specify desired operating shaft catalog number (page L48)
• Specify desired accessories (page L49)
Time delay fuses may be required to utilize the disconnect switch at its maximum
horsepower rating.
Only UL listed Class J and CSA Certified HRCI-J fuses are suitable for use with
these disconnect switches.
Non-fused disconnect switches must use separately installed UL Listed Class J, CC
or T fuses or CSA Certified HRCI-J fuses.
L46 Discount Schedule B-7
http://www.Datasheet4U.com

line_dark_gray
L10-NA300P3 equivalent
Disconnect Switches
Series L10
L10 Enclosed Motor Disconnects (UL and CSA Approved Enclosures)
Type 3/4/12
Watertight, Dusttight
Sheetmetal Enclosure - IP66
Type 4/4X
Watertight, Corrosion-Resistant
Stainless Steel Enclosure - IP66
Type 4/4X
Watertight, Corrosion-Resistant
Non-metallic Enclosure - IP66
Amp/Horsepower
Rating
UL/
CSA
Amps
30
60
100
200
400
30
60
100
200
400
Horsepower
1Ø (60 Hz)
3Ø (60 Hz)
120V 240V 200V 240V 460V 600V Catalog Number Price
Catalog Number
Non-Fused
o b s o l e t e2 3 7.5 7.5 15 20 L10-FN030P3
3 10 15 15 30 50 L10-FN060P3
561 A2 L10-CN030P3
993 B2 L10-CN060P3
~ 7.5 ~ 30 60 75 L10-FN100P3 1433 C1 L10-CN100P3
~ 10 ~ 60 125 150 L10-FN200P3 2390 D1 L10-CN200P3
~ ~ 100 125 250 300 L10-FN400P3 4402 F1 L10-CN400P3
Class J Fused
o b s o l e t e2 3 7.5 7.5 15 20 L10-FJ030P3
3 10 15 15 30 50 L10-FJ060P3
847 A1 L10-CJ030P3
1053 B1 L10-CJ060P3
~ 7.5 ~ 30 60 75 L10-FJ100P3 1433 C1 L10-CJ100P3
~ 10 ~ 60 125 150 L10-FJ200P3 2390 D1 L10-CJ200P3
~ ~ 100 125 250 300 L10-FJ400P3 4402 F1 L10-CJ400P3
NOTE: All Enclosed Disconnects come standard with a black
handle with ON/OFF marking. For a yellow and red handle, add
suffix “E” to the end of the catalog number. Example: change L10-
FN030P3 to L10-FN030P3E.
L
Price Catalog Number Price
1056 A2 L10-KN030P3
1337 B2 L10-KN060P3
2629 C1 L10-KN100P3
3695 D1 L10-KN200P3
7064 F1 L10-KN400P3
561 A2
993 B2
1433 C1
2389 D1
4401 F1
1217 A1 L10-KJ030P3
1398 B1 L10-KJ060P3
2629 C1 L10-KJ100P3
3695 D1 L10-KJ200P3
7064 F1 L10-KJ400P3
850 A1
1053 B1
1433 C1
2389 D1
4401 F1
L50 Discount Schedule B-7


line_dark_gray

Preview 5 Page


Part Details

On this page, you can learn information such as the schematic, equivalent, pinout, replacement, circuit, and manual for L10-NA300P3 electronic component.


Information Total 14 Pages
Link URL [ Copy URL to Clipboard ]
Download [ L10-NA300P3.PDF Datasheet ]

Share Link :

Electronic Components Distributor


An electronic components distributor is a company that sources, stocks, and sells electronic components to manufacturers, engineers, and hobbyists.


SparkFun Electronics Allied Electronics DigiKey Electronics Arrow Electronics
Mouser Electronics Adafruit Newark Chip One Stop


Featured Datasheets

Part NumberDescriptionMFRS
L10-NA300P3The function is UL/CSA Fused Disconnect Switches. Sprecher SchuhSprecher Schuh

Semiconductors commonly used in industry:

1N4148   |   BAW56   |   1N5400   |   NE555   |  

LM324   |   BC327   |   IRF840  |   2N3904   |  



Quick jump to:

L10-     1N4     2N2     2SA     2SC     74H     BC     HCF     IRF     KA    

LA     LM     MC     NE     ST     STK     TDA     TL     UA    



Privacy Policy   |    Contact Us     |    New    |    Search