Número de pieza | LC420DUJ-SGE1 | |
Descripción | WUXGA TFT LCD | |
Fabricantes | LG | |
Logotipo | ||
Hay una vista previa y un enlace de descarga de LC420DUJ-SGE1 (archivo pdf) en la parte inferior de esta página. Total 30 Páginas | ||
No Preview Available ! Product Specification
SPECIFICATION
FOR
APPROVAL
LC420DUJ
( ) Preliminary Specification
( ● ) Final Specification
Title
BUYER
MODEL
KONKA
42.0” WUXGA TFT LCD
SUPPLIER
LG.Display Co., Ltd.
*MODEL
LC420DUJ
SUFFIX
SGE1 (RoHS Verified)
*When you obtain standard approval,
please use the above model name without suffix
APPROVED BY
/
SIGNATURE
DATE
APPROVED BY
J.T. Kim / Team Leader
SIGNATURE
DATE
REVIEWED BY
/ Y.J. Heo / Project Leader
/
Please return 1 copy for your confirmation with
your signature and comments.
Ver. 1.0
PREPARED BY
M.S. Park / Engineer
TV Products Development Dept.
LG. Display LCD Co., Ltd
0 /43
1 page Product Specification
LC420DUJ
2. Absolute Maximum Ratings
The following items are maximum values which, if exceeded, may cause faulty operation or permanent damage
to the LCD module.
Table 1. ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Value
Min Max
Unit
Note
Power Input Voltage LCD Circuit
T-Con Option Selection Voltage
Operating Temperature
Storage Temperature(without packing)
Panel Front Temperature
Operating Ambient Humidity
Storage Humidity
VLCD
VLOGIC
TOP
TST
TSUR
HOP
HST
-0.3
-0.3
0
-20
-
10
5
+14.0
+4.0
+50
+60
+68
90
90
VDC
VDC
°C
°C
°C
%RH
%RH
1
2,3
4
2,3
Note1. Ambient temperature condition (Ta = 25 2 °C )
2. Temperature and relative humidity range are shown in the figure below.
Wet bulb temperature should be Max 39°C, and no condensation of water.
3. Gravity mura can be guaranteed below 40°C condition.
4. The maximum operating temperatures is based on the test condition that the surface temperature
of display area is less than or equal to 68°C with LCD module alone in a temperature controlled chamber.
Thermal management should be considered in final product design to prevent the surface temperature of
display area from being over 68℃. The range of operating temperature may be degraded in case of
improper thermal management in final product design.
90%
60
60%
Ver. 1.0
Wet Bulb
Temperature [°C]
50
40
30
40%
20
10
0
10%
5%
-20 0 10 20 30 40 50 60 70 80
Dry Bulb Temperature [°C]
Storage
Operation
4 /43
5 Page Product Specification
3-4-2. LVDS Input Signal Characteristics
1) DC Specification
LVDS -
LC420DUJ
LVDS +
# V CM = {( LVDS +) + ( LVDS - )}/2
0V
Description
Symbol
LVDS Common mode Voltage
LVDS Input Voltage Range
Change in common mode Voltage
VCM
VIN
ΔVCM
Min
1.0
0.7
-
2) AC Specification
Tclk
LVDS Clock
V CM
V IN _ MAX V IN _ MIN
Max Unit
1.5 V
1.8 V
250 mV
notes
-
-
-
LVDS Data
LVDS 1’st Clock
LVDS 2nd Clock
t tSKEW SKEW
( Fclk = 1 /Tclk )
Tclk
tSKEW_min tSKEW_max
Description
LVDS Differential Voltage
LVDS Clock to Data Skew
Effective time of LVDS
LVDS Clock to Clock Skew (Even to Odd)
Symbol
VTH
VTL
tSKEW
teff
tSKEW_EO
Min
100
-600
-
|± 360|
-
Max
600
-100
|(0.25*Tclk)/7|
-
|1/7* Tclk|
Unit
mV
mV
ps
ps
ps
notes
Tested with Differential Probe
2
-
-
-
notes 1. All Input levels of LVDS signals are based on the EIA 644 Standard.
2. LVDS Differential Voltage is defined within teff
Ver. 1.0
10 /43
11 Page |
Páginas | Total 30 Páginas | |
PDF Descargar | [ Datasheet LC420DUJ-SGE1.PDF ] |
Número de pieza | Descripción | Fabricantes |
LC420DUJ-SGE1 | WUXGA TFT LCD | LG |
Número de pieza | Descripción | Fabricantes |
SLA6805M | High Voltage 3 phase Motor Driver IC. |
Sanken |
SDC1742 | 12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters. |
Analog Devices |
DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares, |
DataSheet.es | 2020 | Privacy Policy | Contacto | Buscar |