DataSheet.es    


PDF TSol503 Data sheet ( Hoja de datos )

Número de pieza TSol503
Descripción Temperature Controller
Fabricantes TiEmme 
Logotipo TiEmme Logotipo



Hay una vista previa y un enlace de descarga de TSol503 (archivo pdf) en la parte inferior de esta página.


Total 12 Páginas

No Preview Available ! TSol503 Hoja de datos, Descripción, Manual

H
S
TSol503
Temperature Controller
for Thermic Solar Panel Systems
GB
Pag. 1 / 12
TSol503 Manual V1.0

1 page




TSol503 pdf
5 Default Functions
5.1 Boiler/Pool Management
Parameters of the management of Boiler/Pool charge
DESCRIPTION
Running’s Thermostat Boiler/Pool on S3
Hysteresis thermostat THS300
Differential thermostat (S1-S2) for Boiler/pool charge
Thermostat hysteresis THS102
Thermostat of minimum on S1 under the solar circuit pump is deactivated
Thermostat hysteresis THS102
Thermostat on S2 over the Cooling Function Boiler is activated through the Cooling and/or Solar Circuit
Hysteresis thermostat THS202
Thermostat of maximum on S2 that Boiler/Pool can reach
Thermostat hysteresis THS203
Code
THS300
HYS300
THD120
HYD120
THS102
HYS102
THS202
HYS202
THS203
HYS203
5.2 Sanitary Increasing
Parameters for the Sanitary Valve management
DESCRIPTION
Thermostat on S3 over the Sanitary Valve is deviated to the sanitary water output
Thermostat hysteresis THS305
Code
THS305
HYS305
5.3 Boiler Integration
Parameters for the Integration Boiler management
DESCRIPTION
Thermostat on S3 under the Boiler Integration output is activated
Thermostat hysteresis THS302
Code
THS302
HYS302
5.4 Solar Circuit Cooling
Parameters for the Cooling management of the solar circuit for over temperature.
DESCRIPTION
Thermostat on S1 over the collector fluid is convoyed to the Cooler
Thermostat hysteresis THS104
Thermostat on S1 over the solar pump charges the boilers/pool and takes them to the maximum
thermostats.
Thermostat hysteresis THS100
Maximum thermostat on S3 Boiler/Pool
Thermostat hysteresis THS303
Thermostat on S1 over the solar pump charge boiler is blocked
Thermostat hysteresis THS103
Code
THS104
HYS104
THS100
HYS100
THS303
HYS303
THS103
HYS103
5.5 Panel Protection
In the following schema are the thermostats and hysteresis of the function panel’s protection managed for example
with a tent/shutter to cover the panel
DESCRIPTION
Code
Thermostat on S1 over the output Protection Panel is activated (ex. Shutter/tent)
THS103
Thermostat hysteresis THS103
HYS103
6 Menu
The Menu is divided in:
Installer Menu where are available all the parameters of TSol503
User’s menu where are available only the parameters reserved to the final user
Pag. 5 / 12
TSol503 Manual V1.0

5 Page





TSol503 arduino
8 Thermostats and Parameters
Description
Code
Differential thermostat (S1-S2)
to activate the Boiler Charge
THD120 hysteresis
Thermostat differential (S1-S3)
to activate Stratification
Thermostat on S1 over the Solar Pump
charges the Boiler until the Maximum
Thermostats
THS100 hysteresis
Thermostat on S1 under the function De-Ice
is activated
THS101 hysteresis
Thermostat on S1 under the Solar Pump is
deactivated
THS102 hysteresis
Thermostat on S1 over the Solar Pump is
blocked
THS103 hysteresis
Thermostat on S1 over the collector fluid is
sent to the Cooler
THS104 hysteresis
Thermostat on S2, over the Boiler is cooled
with negative differential S1-S2.
THS201 hysteresis
Thermostat on S2 over the function Boiler
cooling is activated through the solar circuit
THS202 hysteresis
Thermostat of maximum on S2 the
boiler/pool can reach
THS203 hysteresis
THD120
HYD120
THD130
THS100
HYS100
THS101
HYS101
THS102
HYS102
THS103
HYS103
THS104
HYS104
THS201
HYS201
THS202
HYS202
THS203
HYS203
Boiler/Pool Running’s Thermostat on S3 THS300
THS300 hysteresis
Thermostat on S1 and S3 under the Bucket
Charge is activated
THS301 hysteresis
Thermostat on S3 under the Boiler
Integration is activated
THS302 hysteresis
Thermostat of maximum on S3
the Boiler/Pool can reach
THS303 hysteresis
Thermostat on S3 over the Sanitary Valve is
deviated to the sanitary water output
THS305 hysteresis
HYS300
THS301
HYS301
THS302
HYS302
THS303
HYS303
THS305
HYS305
Function
Boiler/Pool Charge
Stratification
Collector protection
De-Ice
Boiler/Pool Charge
Collector Protection
Cooling
Holiday
Boiler Protection
Boiler/Pool Protection
Boiler/Pool Charge
Bucket Charge
Boiler/Pool Charge
Boiler/Pool Protection
Sanitary Increasing
Range
Min Set Max
U
1 6 30 °C
1 2 5 °C
1 3 30 °C
80 95 200 °C
0 2 25 °C
-20 5 30 °C
0 2 25 °C
0 30 40 °C
0 2 25 °C
80 100 200 °C
0 2 25 °C
70 100 200 °C
0 20 30 °C
20 60 85 °C
0 2 25 °C
20 85 100 °C
0 2 25 °C
20 80 100 °C
0 2 25 °C
10 70 85 °C
0 2 25 °C
20 45 85 °C
0 2 25 °C
20 50 85 °C
0 2 25 °C
20 90 100 °C
0 2 25 °C
20 50 85 °C
0 2 25 °C
Pag. 11 / 12
TSol503 Manual V1.0

11 Page







PáginasTotal 12 Páginas
PDF Descargar[ Datasheet TSol503.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
TSol503Temperature ControllerTiEmme
TiEmme

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar