SINAMICS S120 drive system
Booksize format for Line and Motor Modules
Active Line Modules in booksize format
Overview
Design (continued)
The scope of supply of the Active Line Modules includes:
• DRIVE-CLiQ cable for connection to the Control Unit for drive
control on the immediate left
• DRIVE-CLiQ cable (length depends on module width) to
connect Active Line Module to adjacent Motor Module
• 2 blanking plugs for sealing unused DRIVE-CLiQ sockets
• Jumper for connecting the 24 V DC busbar to the adjacent
Motor Module
• 24 V terminal adapter
• Connector X21 for digital inputs
• Fan insert for the 80 kW (100 HP) and 120 kW (150 HP) Active
Line Modules is supplied with the modules. The voltage for the
fan insert is supplied by the Active Line Module.
• 1 set of warning signs in foreign languages
Integration
The self-commutated feed/feedback units (with IGBTs in infeed
and regenerative feedback directions) generate a regulated DC
link voltage. This means that the connected Motor Modules are
decoupled from the line voltage. Line voltage fluctuations within
the permissible supply tolerances have no effect on the motor
voltage. Active Line Modules are designed for connection to
grounded-neutral (TN, TT) and non-grounded (IT) supply
systems.
The Active Line Module communicates via DRIVE-CLiQ with the
CU320 Control Unit, SINUMERIK 802D sl,
SINUMERIK 840D sl with NCU 710.1/NCU 720.2/NCU 730.1/
NCU 730.2 PN or with the Numeric Control
Extensions NX10/NX15 and receives its control information from
these sources.
The DC link is pre-charged via integrated precharging resistors.
In order to operate an Active Line Module, it is absolutely
essential to use the appropriate Active Interface Module or
matching line reactor.
Design
The Active Line Modules in booksize format feature the following
interfaces as standard:
• 1 line connection via screw-type terminals
• 1 connection for the 24 V DC electronics power supply via the
24 V terminal adapter included in the scope of supply
• 1 DC link connection via integrated DC link busbars
• 3 DRIVE-CLiQ sockets
• 2 PE (protective earth) connections
The status of the Active Line Modules is indicated via two
multi-color LEDs.
On the 100 mm (3.94 in) wide Active Line Module, the shield for
the power supply cable can be connected to the integrated
shield connection plate via a shield connection terminal or tube
clip, e.g. Weidmüller type KLBÜ CO 4. The shield connection
terminal must not be used for strain relief. Shield connection
plates are available for the 150 mm (5.91 in), 200 mm (7.87 in)
and 300 mm (11.81 in) wide modules.
The signal cable shield can be connected to the Line Module by
means of a shield connection terminal, e.g. type KLBÜ 3-8 SC
by Weidmüller.
9
Siemens NC 61 · 2007/2008
9/35

1 page




6SL3130-7TE28-0AA3 pdf
Characteristic curves
Overload capability
max
rated
0.25 s
10 s
Duty cycle with previous load
max
S6
rated
0.7 x rated
4 min
10 min
S6 duty cycle with previous load
max
rated
0.7 x rated
10 s
60 s
S6 duty cycle with previous load
© Siemens AG 2007
SINAMICS S120 drive system
Booksize format for Line and Motor Modules
Active Line Modules in booksize format
Derating characteristics
100
%
90
80
70
60
30 35 40 45 50 °C 55
(86)
(95)
(104)
(113)
(122) (°F) (131)
t Ambient temperature
Output power dependent on ambient temperature
100
%
95
90
85
80
75
70
65
60
0
1000
2000
3000
4000 m 5000
t
(3282)
(6563)
(9845)
(13126) (ft) (16408)
Installation altitude above sea level
Output power dependent on installation altitude
100
G_D211_EN_00006a
1.0
90 0.9
80
t
0.8
70 0.7
0
1000
2000
3000 m 4000
(3282)
(6563)
(9845) (ft) (13126)
Installation altitude above sea level
Voltage derating dependent on installation altitude
100
%
80
with HFD line reactor
and HFD resistor
60
40
350 m (1148 ft) (shielded)
630 m (2067 ft) (shielded)
560 m (1837 ft) (unshielded) 850 m (2789 ft) (unshielded)
Cable length in total
Output power with Active Line Module dependent on total cable length
9
Siemens NC 61 · 2007/2008
9/39

5 Page





6SL3130-7TE28-0AA3 arduino
Overview
© Siemens AG 2007
SINAMICS S120 drive system
Booksize format for Line and Motor Modules
Active Line Modules in booksize format
Basic Line Filters
Basic Line Filters are designed for use on machines on which
conducted interference emissions in the frequency range
between 150 kHz and 30 MHz need to be damped in
accordance with the requirements of CE EMC legislation.
The use of Basic Line Filters is subject to the following general
conditions:
• The machine/system must only be used in industrial power
systems
• No. of axes <12
• Total cable length <150 m (492 ft)
• The machine manufacturer (OEM ) must have the CE
conformity of the machine/system confirmed by an
accredited EMC test laboratory (e.g. by EPCOS;
Technical specifications
Line voltage 380 ... 480 V 3 AC
Order No.
Product name
Rated current
Power loss
Line/load connection
L1, L2, L3/U, V, W
• Conductor cross-section
PE connection
Degree of protection
Dimensions
• Width
• Height
• Depth
Weight, approx.
Approvals
Suitable for Active Line Module
in booksize format
• Rated infeed power of the
Active Line Module
A
kW
mm2
6SL3000-0BE21-6DA0
Basic Line Filter
36
0.006
Screw-type terminals
6SL3000-0BE23-6DA0
65
0.010
Screw-type terminals
6SL3000-0BE25-5DA0
105
0.015
Screw-type terminals
10
On housing with M6 screw
stud
IP20
35
On housing with M6 screw
stud
IP20
50
On housing with M8 screw
stud
IP20
mm (in)
mm (in)
mm (in)
kg (lb)
Type
kW (HP)
50 (1.97)
420 (16.54)
226 (8.9)
5 (11)
cURus (File No.: E70122)
6SL3130-7TE21-6AA3
6SL3131-7TE21-6AA3
16 (18)
75 (2.95)
420 (16.54)
226 (8.9)
6.5 (14)
cURus (File No.: E70122)
6SL3130-7TE23-6AA3
6SL3131-7TE23-6AA3
36 (40)
100 (3.94)
420 (16.54)
226 (8.9)
11.5 (25)
cURus (File No.: E70122)
6SL3130-7TE25-5AA3
6SL3131-7TE25-5AA3
55 (60)
Selection and Ordering Data
More information
Rated infeed
power of the
Active Line Module
Suitable for
Active Line Module
Order No.
Basic Line Filter
Order No.
You must follow the instructions in the Equipment Manual
when using Basic Line Filters in conjunction with 16 kW
to 55 kW (18 HP to 60 HP) Active Line Modules:
SINAMICS S120 – Power units in booksize format.
Line voltage 380 ... 480 V 3 AC
16 kW (18 HP)
6SL3130-7TE21-6AA3 6SL3000-0BE21-6DA0
6SL3131-7TE21-6AA3
36 kW (40 HP)
6SL3130-7TE23-6AA3 6SL3000-0BE23-6DA0
6SL3131-7TE23-6AA3
55 kW (60 HP)
6SL3130-7TE25-5AA3 6SL3000-0BE25-5DA0
6SL3131-7TE25-5AA3
9
Siemens NC 61 · 2007/2008
9/45

11 Page







PáginasTotal 12 Páginas
PDF Descargar[ Datasheet 6SL3130-7TE28-0AA3.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
6SL3130-7TE28-0AA3Active Line Modules in booksize formatSiemens
Siemens

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar