DataSheet.es    


PDF TLE8458 Data sheet ( Hoja de datos )

Número de pieza TLE8458
Descripción LIN Transceiver
Fabricantes Infineon 
Logotipo Infineon Logotipo



Hay una vista previa y un enlace de descarga de TLE8458 (archivo pdf) en la parte inferior de esta página.


Total 30 Páginas

No Preview Available ! TLE8458 Hoja de datos, Descripción, Manual

TLE8458
LIN Transceiver with integrated Voltage Regulator
TLE8458G
TLE8458GV33
Data Sheet
Rev. 1.1, 2014-04-01
Automotive Power

1 page




TLE8458 pdf
3 Pin Configuration
3.1 Pin Assignments
TLE8458
Pin Configuration
RxD
EN
WK
TxD
Figure 2 Pin Configuration
1
2
3
4
8 VC C
7 VS
6 LIN
5 GND
3.2 Pin Definitions and Functions
Table 1 Pin Definition
Pin Symbol
Function
1 RxD
Receive Data Output;
Low in dominant state, active low after a Wake-up event on BUS or WK pin.
2 EN
Enable Input;
Integrated pull-down resistor, device set to normal operation mode when HIGH.
3 WK
Wake-up Input;
Active LOW, negative edge triggered, internal pull-up.
4 TxD
Transmit Data Input;
Integrated pull-down resistor, LOW in dominant state. Active LOW after Wake-up
via WK pin.
5 GND
Ground
6 LIN
Bus Output / Input;
LIN bus input / Output,
LOW in dominant state,
Internal termination and pull-up current source.
7 VS
8 VCC
Battery Supply Input
Output Voltage;
Decouple to GND with a capacitor CVcc 470 nF, ESR < 6 at 10 kHz,
Active during Normal Mode, disabled in Sleep Mode.
Data Sheet
5 Rev. 1.1, 2014-04-01

5 Page





TLE8458 arduino
TLE8458
Mode Control
5.2.1
Stand-By Mode
The Stand-By Mode is an idle operation mode, which disables the communication to the LIN bus. The TLE8458
enters automatically the Stand-By Mode after a Power-up. By setting the EN pin to HIGH, the operation mode
changes to Normal Operation Mode, regardless of the signal applied to the TxD pin.
The TLE8458 can be transferred to Stand-By mode by the following options:
• After Power-up on the supply VS, the TLE8458 starts in Stand-By Mode.
• From Sleep Mode or from Stop Mode the TLE8458 changes to Stand-By Mode if a Wake-up event occurs on
the LIN bus.
• From Sleep Mode or from Stop Mode the TLE8458 changes to Stand-By Mode if a Wake-up event occurs on
the local Wake input WK.
• In case of an undervoltage event on VS, the TLE8458 changes to Stand-By Mode regardless of selected
operation mode.
In Stand-By mode the external power supply VCC is active and LIN bus output stage is disabled. The TLE8458
provides the following functionality in Stand-By Mode:
• The power supply VCC is active and functional.
• The LIN transceiver output stage is disabled, no communication to the LIN bus is possible.
• The LIN transceiver bus input receiver is disabled.
• The LIN bus is terminated by the 30 kΩ.
• Both digital pins, the TxD pin and the RxD pin act as output pins and indicate a Wake-up or a Power-up event2).
• The EN input pin is active. By setting the EN pin to HIGH the TLE8458 changes the operation mode to Normal
Operation Mode (see Figure 3).
• The Wake-up logic is disabled. Wake-up events don’t trigger an operation mode change.
Table 6 Logic table for Wake-up monitoring1)
Power-up
Wake-up event RxD
TxD2)
Comments
Yes
No
HIGH
LOW
Power Up event
No
Via LIN Bus
LOW
HIGH
Wake-up via LIN Bus
No
Via WK Pin
LOW
LOW
Wake-up via local Wake pin WK
1) The Wake-up monitor is only active in Stand-By Mode
2) The TxD input needs an external termination to indicate a “High” or a “Low” signal. The external termination could be a pull-
up resistor or an active microcontroller output.
5.2.2
Normal Operation Mode
The TLE8458 enters the Normal Operation Mode after the microcontroller sets EN to “High” (see Figure 4). In
Normal Operation mode the LIN bus receiver and the LIN bus transmitter are active. The TLE8458 converts the
logical HIGH and LOW signals on the TxD input pin to DOMINANT and RECESSIVE signals to the LIN bus.
Simultaneously the input receiver of the TLE8458 converts the DOMINANT and RECESSIVE signals on the LIN bus
to HIGH and LOW signals to the RxD output. In Normal Operation mode the output voltage VCC is active and the bus
termination is set to 30 kΩ.
Normal Slope Mode and the Software Flash Mode are Normal Operation Modes. In these two sub-modes the
behavior of the power supply VCC and the bus termination are the same. Per default the TLE8458 always enters
into Normal Slope Mode, either from Sleep Mode, Stop Mode or from Stand-By Mode. The Software Flash Mode
can only be entered from Normal Slope mode.
Data Sheet
11 Rev. 1.1, 2014-04-01

11 Page







PáginasTotal 30 Páginas
PDF Descargar[ Datasheet TLE8458.PDF ]




Hoja de datos destacado

Número de piezaDescripciónFabricantes
TLE8458LIN TransceiverInfineon
Infineon
TLE8458GLIN TransceiverInfineon Technologies
Infineon Technologies
TLE8458GULIN TransceiverInfineon Technologies
Infineon Technologies
TLE8458GUV33LIN TransceiverInfineon Technologies
Infineon Technologies

Número de piezaDescripciónFabricantes
SLA6805M

High Voltage 3 phase Motor Driver IC.

Sanken
Sanken
SDC1742

12- and 14-Bit Hybrid Synchro / Resolver-to-Digital Converters.

Analog Devices
Analog Devices


DataSheet.es es una pagina web que funciona como un repositorio de manuales o hoja de datos de muchos de los productos más populares,
permitiéndote verlos en linea o descargarlos en PDF.


DataSheet.es    |   2020   |  Privacy Policy  |  Contacto  |  Buscar